Gimax 32 A Three-Phase Distribution Board
25,00 € + VAT
The Gimax 32 A three-phase distribution board is a portable 400 V 32 A 3P+N power distribution unit for film and television productions, events and temporary installations. Available for hire from Sidereus in Milan, it supplies three single-phase 16 A CEE sockets and three 16 A Schuko/Italian dual-standard sockets, each with its own circuit breaker.
Features
- – Input: 400 V 32 A CEE-P17 3P+N+E
- – Outputs: 3 × 230 V 16 A CEE and 3 × 10/16 A Schuko/Italian dual-standard sockets
- – Main protection: 4-pole 40 A / 30 mA residual-current device
- – Output protection: 6 × 1P+N 16 A type C circuit breakers
Details
Enclosure and power input
The Gimax OMEGA 32 A has a double-insulated hard butyl rubber enclosure. The material is self-extinguishing and resistant to oils, acids, petrol, industrial solvents, impact and crushing. The transparent cover is made of shatterproof polycarbonate and has an AISI 304 stainless-steel spring-return latch and a sealing gasket. The enclosure is rated IP54 and operates from −20 °C to +80 °C. Power is supplied through approximately 2 metres of flexible H07RN-F 5G6 mm² cable, terminated with a 400 V 32 A CEE-P17 3P+N+E plug rated IP44.
Distribution and protection
The board supplies six separate single-phase outlets: three 230 V 16 A CEE-P17 2P+E sockets and three 250 V 10/16 A sockets that accept Italian and Schuko plugs. All outlets are rated IP44. The Gimax board takes a 32 A three-phase supply and provides three Schuko and three single-phase 16 A CEE outlets. Each outlet is protected by a 16 A type C 1P+N circuit breaker with a breaking capacity of 4.5 kA. A four-pole 40 A residual-current circuit breaker upstream has a 30 mA trip sensitivity. This setup distributes multiple single-phase loads from one 32 A three-phase line. Separate protection on all six outlets makes the distribution easier to manage on set.
Safety and professional use
Use this 400 V 32 A three-phase board only within an electrical installation that has been checked and rated for the load. The built-in protective devices do not replace checks on the upstream supply. Check protective conductor continuity, the combined current draw of the connected equipment and the balance of loads across phases. Competent personnel must handle connection, distribution and commissioning. Follow the electrical procedures for the set, event or temporary installation. The enclosure measures approximately 270 × 290 × 270 mm and has a rubber handle and four feet. The unit is CE marked and Class II.
The Gimax 32 A three-phase distribution board is available for hire from Sidereus in Milan. It provides compact, portable and protected power distribution for film sets, events and productions with lighting departments that need several single-phase outlets from a five-pin 32 A CEE supply.